Cisco Catalyst 2950T-24 Ethernet Switch 24FE 2GE Rack Ears Max Mem, Max Flash S-1This sale is for one cisco Systems switch
cisco SystemsCatalyst 2950T-24 SwitchEthernet Switch24 FastEthernet/IEEE 802.3 interface(s)
2 Gigabit Ethernet/IEEE 802.3 interface(s)IOS image installed: Version 12.1(22)EA11Maximum memory installed: 19912K bytes of memoryMaximum flash installed: Total bytes: 7741440This switch is labeled S-1 in the photos.
Included:
- One 2950T-24 Ethernet switch
- Two rack ears
- One power cord
- Maximum memory and flash
- Two cross-over twisted pair Ethernet cables (cat 5e)
Specifications:cisco WS-C2950T-24 (RC32300) processor (revision P0) with 19912K bytes of memory.24 FastEthernet/IEEE 802.3 interface(s)
2 Gigabit Ethernet/IEEE 802.3 interface(s)Running Enhanced Image
IOS (tm) C2950 Software (C2950-I6K2L2Q4-M), Version 12.1(22)EA11, RELEASE SOFTWARE (fc2)
C2950 Boot Loader (C2950-HBOOT-M) Version 12.1(11r)EA1
[ Enhanced Image supports 250 VLANs ]32K bytes of flash-simulated non-volatile configuration memory.
flashfs[1]: Total bytes: 7741440
Condition:This cisco switch is used but is still in good condition.All 26 ports have been tested and function properly.There may be a few scuff marks on the case.This switch is labeled S-1 in the photos. The flat metal structure surrounding the console port was slightly bent but has been flattened in place. This does not affect the operation of the switch.Detailed output from a reboot and from the show version command is at the end of this listing.
History:This cisco switch served in my lab for many years as I taught authorized and customized networking courses including CCIE Prep classes, BGP, MPLS, IPv6, and basic CCNP-level courses.The time has come for this switch to go to a new home. I hope it will be useful to a student who is studying for networking certifications.
Shipping:Shipping will be by USPS Ground Advantage.Combined shipping is available for buyers who purchase more than one switch.
Note:* This listing is for the Switch labeled S-1. Switches S-2 through S-8 are currently available and will be listed sequentially ( permits only one of my switches to be listed at a time since they are considered "duplicate" listings). I will group several switches together in a new listing if a potential buyer makes such a request. *Detailed Specifications: (reboot and show version command output)S-1#
S-1#rel
Proceed with reload? [confirm]01:00:32: %SYS-5-RELOAD: Reload requestedC2950 Boot Loader (C2950-HBOOT-M) Version 12.1(11r)EA1, RELEASE SOFTWARE (fc1)
Compiled Mon 22-Jul-02 17:18 by antonino
WS-C2950T-24 starting...
Base ethernet MAC Address: 00:0f:90:76:1f:40
Xmodem file system is available.
Initializing Flash...
flashfs[0]: 80 files, 3 directories
flashfs[0]: 0 orphaned files, 0 orphaned directories
flashfs[0]: Total bytes: 7741440
flashfs[0]: Bytes used: 6730752
flashfs[0]: Bytes available: 1010688
flashfs[0]: flashfs fsck took 9 seconds.
...done initializing flash.
Boot Sector Filesystem (bs:) installed, fsid: 3
Parameter Block Filesystem (pb:) installed, fsid: 4
Loading uncompressed and installed, entry point: 0x80010000
executing... Restricted Rights LegendUse, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013. cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706Cisco Internetwork Operating System Software
IOS (tm) C2950 Software (C2950-I6K2L2Q4-M), Version 12.1(22)EA11, RELEASE SOFTWARE (fc2)
Copyright (c) 1986-2008 by cisco Systems, Inc.
Compiled Tue 08-Jan-08 11:12 by amvarma
Image text-base: 0x80010000, data-base: 0x80680000
Initializing flashfs...
flashfs[1]: 80 files, 3 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 7741440
flashfs[1]: Bytes used: 6730752
flashfs[1]: Bytes available: 1010688
flashfs[1]: flashfs fsck took 9 seconds.
flashfs[1]: Initialization complete.
Done initializing flashfs.
POST: System Board Test : Passed
POST: Ethernet Controller Test : Passed
ASIC Initialization PassedPOST: FRONT-END LOOPBACK TEST : Passed
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.A summary of U.S. laws governing Cisco cryptographic products may be found you require further assistance please contact us by sending email to
< cisco export email address removed by >cisco WS-C2950T-24 (RC32300) processor (revision P0) with 19912K bytes of memory.
Processor board ID FOC0814W0A4
Last reset from system-reset
Running Enhanced Image
24 FastEthernet/IEEE 802.3 interface(s)
2 Gigabit Ethernet/IEEE 802.3 interface(s)32K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address: 00:0F:90:76:1F:40
Motherboard assembly number: 73-6114-10
Power supply part number: 34-0965-01
Motherboard serial number: FOC08130NY6
Power supply serial number: DAB08135AF6
Model revision number: P0
Motherboard revision number: A0
Model number: WS-C2950T-24
System serial number: FOC0814W0A4
Press RETURN to get started!
00:00:17: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
00:00:22: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
00:00:22: %SYS-5-CONFIG_I: Configured from memory by console
00:00:22: %SYS-5-RESTART: System restarted --
Cisco Internetwork Operating System Software
IOS (tm) C2950 Software (C2950-I6K2L2Q4-M), Version 12.1(22)EA11, RELEASE SOFTWARE (fc2)
Copyright (c) 1986-2008 by cisco Systems, Inc.
Compiled Tue 08-Jan-08 11:12 by amvarma
00:00:22: %SNMP-5-COLDSTART: SNMP agent on host S-1 is undergoing a cold start
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/9, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/10, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/13, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/14, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/15, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/16, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/17, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/18, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/19, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/20, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/21, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/22, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface FastEthernet0/23, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
00:00:23: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
00:00:36: %LINK-3-UPDOWN: Interface FastEthernet0/11, changed state to up
00:00:37: %LINK-3-UPDOWN: Interface FastEthernet0/12, changed state to up
00:00:38: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/11, changed state to up
00:00:39: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/12, changed state to up
00:01:17: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/11, changed state to down
00:01:17: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/12, changed state to down
00:01:18: %LINK-3-UPDOWN: Interface FastEthernet0/11, changed state to down
00:01:18: %LINK-3-UPDOWN: Interface FastEthernet0/12, changed state to down
00:01:25: %LINK-3-UPDOWN: Interface FastEthernet0/11, changed state to up
00:01:25: %LINK-3-UPDOWN: Interface FastEthernet0/12, changed state to up
00:01:27: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/11, changed state to up
00:01:28: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/12, changed state to up
00:01:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan99, changed state to upUser Access ver
Cisco Internetwork Operating System Software
IOS (tm) C2950 Software (C2950-I6K2L2Q4-M), Version 12.1(22)EA11, RELEASE SOFTWARE (fc2)
Copyright (c) 1986-2008 by cisco Systems, Inc.
Compiled Tue 08-Jan-08 11:12 by amvarma
Image text-base: 0x80010000, data-base: 0x80680000ROM: Bootstrap program is C2950 boot loaderS-1 uptime is 6 minutes
System returned to ROM by power-on
System image file is product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.A summary of U.S. laws governing Cisco cryptographic products may be found you require further assistance please contact us by sending email to
< cisco export email address removed by >.cisco WS-C2950T-24 (RC32300) processor (revision P0) with 19912K bytes of memory.
Processor board ID FOC0814W0A4
Last reset from system-reset
Running Enhanced Image
24 FastEthernet/IEEE 802.3 interface(s)
2 Gigabit Ethernet/IEEE 802.3 interface(s)32K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address: 00:0F:90:76:1F:40
Motherboard assembly number: 73-6114-10
Power supply part number: 34-0965-01
Motherboard serial number: FOC08130NY6
Power supply serial number: DAB08135AF6
Model revision number: P0
Motherboard revision number: A0
Model number: WS-C2950T-24
System serial number: FOC0814W0A4
Configuration register is 0xFS-1>